[PDF]
http://dx.doi.org/10.3952/lithjphys.48407
Open access article / Atviros prieigos straipsnis
Lith. J. Phys. 48, 349–355 (2008)
HEAVY METAL PENETRATION INTO THE
HUMAN RESPIRATORY TRACT IN VILNIUS
Darius Valiulis, Jonas Šakalys, and Kristina Plauškaitė
Institute of Physics, Savanorių 231, LT-02300 Vilnius,
Lithuania
E-mail: sakalys@ar.fi.lt
Received 28 August 2008; revised 19
November 2008; accepted 4 December 2008
The peculiarities of the aerosol
particle deposition in the human respiratory tract depending on
the particle size and the breathing rate have been analysed. The
highest deposition efficiency (0.85) was determined for the
largest particles (10–20
m) and the
lowest efficiency (0.28) for the finer particles (0.3
μm).
The heavy metal amount penetrating into the human respiratory
tract at a different breathing rate in Vilnius has been evaluated.
It has been determined that the deposition efficiency of heavy
metals in the human respiratory tract changes insignificantly with
the increase in the breathing rate, and when the breathing rate
increases threefold (from 10 to 30 L min
–1)
the efficiency decreases only by about 10%. On the average, about
60% of heavy metals in the inhaled air penetrate into the
respiratory tract. The comparison of Pb, V, and Zn concentrations
in Vilnius city with those at the Preila background station has
shown that they differ up to two times. It means that the
contribution to the pollution with these metals in Vilnius city is
insubstantial, and there is no considerable threat to human
health.
Keywords: heavy metals, concentration,
air, aerosol particles, human respiratory tract, efficiency
PACS: 92.60.Mt, 92.20.Bk, 87.19.xg
SUNKIŲJŲ METALŲ PATEKIMAS Į
ŽMOGAUS KVĖPAVIMO TAKUS VILNIUJE
Darius Valiulis, Jonas Šakalys, Kristina Plauškaitė
Fizikos institutas, Vilnius, Lietuva
Dėl intensyvios antropogeninės žmogaus veiklos
ir miestų transporto gausos pasaulyje padidėjo oro tarša aerozolio
dalelėmis. Šių dalelių sudėtyje yra įvairios kilmės toksinių
medžiagų, alergenų ir sunkiųjų metalų, todėl ore esančios smulkios
aerozolio dalelės yra žalingos žmogaus sveikatai. Patekusios į
plaučius jos gali sukelti kvėpavimo takų ir kitas ligas.
Priklausomai nuo gyvenimo būdo, suaugęs žmogus vidutiniškai
įkvepia per dieną 15000 litrų oro. Darbo tikslas buvo įvertinti
sunkiųjų metalų kiekius, su aerozolio dalelėmis patenkančius į
žmonių kvėpavimo takus Vilniuje. Aerozolio dalelių bandiniai
sunkiųjų metalų analizei buvo imami prie Vilniaus televizijos
bokšto 1999 m. spalio 28 d. – gruodžio 20 d. ir Vilniaus
senamiesčio užterštumo tyrimo stotelėje 2001 m. balandžio 28 d. –
gegužės 17 d. Imant bandinius buvo registruojamas ir aerozolio
dalelių dydžių spektras. Buvo nustatyta aerozolio dalelių
sulaikymo žmogaus kvėpavimo takuose efektyvumo priklausomybė nuo
dalelių dydžio ir kvėpavimo greičio. Atliekant eksperimentą buvo
ištirti šeši 20–60 metų amžiaus atsitiktinai parinkti žmonės.
Tyrimai buvo atliekami įkvepiant orą pro nosį ir iškvepiant pro
burną skirtingais greičiais intervale nuo 10 iki 32 l min
–1.
Efektyvumas kito nuo 0,85 didžiosioms (10–20
m) iki
0,28 mažosioms (0,3
m)
dalelėms. Iš šių duomenų nustatytas sunkiųjų metalų kiekis,
galintis patekti į žmogaus kvėpavimo takus Vilniuje. Lyginant Pb,
V ir Zn koncentracijas Vilniuje su šių metalų koncentracijomis
Preilos foninėje stotyje matyti, kad jos skiriasi daugiausia iki
dviejų kartų. Tai rodo, kad Vilniuje šių metalų šaltiniai nebuvo
stiprūs ir žymesnio pavojaus žmonių sveikatai nekėlė. Nustatyta,
kad didėjant kvėpavimo greičiui, sunkiųjų metalų nusėdimas mažėja
nedaug, o kvėpavimo greičiui išaugus trigubai, efektyvumas
sumažėja tik apie 10 %. Vidutiniškai apie 60 % (
= 6 %)
sunkiųjų metalų, esančių įkvepiamame ore, patenka į kvėpavimo
takus.
References / Nuorodos
[1] J.E. Fergusson, The Heavy Elements: Chemistry, Environmental
Impact, and Health Effects (Pergamon Press, Oxford, England,
1990),
https://www.amazon.co.uk/Heavy-Elements-Chemistry-Environmental-Effects/dp/0080402755/
[2] J. Šakalys, K. Kvietkus, and D. Valiulis, Variation tendencies
of heavy metal concentrations in the air and precipitation, Environ.
Chem. Phys., 26(2), 61–67 (2004)
[3] C. Barbante, G. Cozzi, G. Capodaglio, K. van de Velde, C.
Ferrari, A. Veysseyre, C.F. Boutron, G. Scarponi, and C. Paolo,
Determination of Rh, Pd and Pt in polar and alpine snow and ice by
double-focusing ICPMS with microconcentric nebulization, Anal. Chem.
71, 4125–4133 (1999),
http://dx.doi.org/10.1021/ac981437g
[4] Aerosols: Research, Risk Assesment and Control Strategies,
eds. S.D. Lee, T. Schneider, L.D. Grant, and P.J. Verkerk (Lewis
Publishers, Chelsea, MI, USA, 1986) pp. 521–549,
https://www.amazon.co.uk/Aerosols-Research-Assessment-Control-Strategies/dp/0873710517/
[5] P. Žebrauskas and J. Valiūnienė, Human Anatomy and
Physiology (Vilnius, 1987) [in Lithuanian]
[6] M. Berico, A. Luciani, and M. Formignani, Atmospheric aerosol in
an urban area measurements of TSP and PM10 standards and pulmonary
deposition assessments, Atmos. Environ. 31(21), 3659–3665
(1997),
http://dx.doi.org/10.1016/S1352-2310(97)00204-5
[7] L. Gradon and A. Podgorski, Kinetics of particle retention in
the human respiratory tract, Ann. Occup. Hyg. 35(3), 249–259
(1991),
http://dx.doi.org/10.1093/annhyg/35.3.249
[8] O.G. Raabe, Comparision of the criteria for sampling inhalable
and respirable aerosols, Ann. Occup. Hyg. 26(1), 33–44
(1982),
http://dx.doi.org/10.1093/annhyg/26.1.33
[9] E.J. Calabrese and E.M. Kenyon, Air Toxics and Risk
Assessment (Lewis Publishers, 1991),
https://www.amazon.co.uk/Toxics-Assessment-Toxicology-Environmental-Health/dp/0873711653/
[10] D. Valiulis, D. Čeburnis, J. Šakalys, and K. Kvietkus,
Estimation of atmospheric trace metal emissions in Vilnius city,
Lithuania, using vertical concentration gradient and road tunnel
measurement data, Atmos. Environ. 36(39–40), 6001–6014
(2002),
http://dx.doi.org/10.1016/S1352-2310(02)00764-1
[11] V. Ulevičius, A. Juozaitis, and D. Šopauskienė, A high
efficiency virtual impactor: Design and performance, Environ. Phys.
20(2), 20–26 (1998)
[12] D. Čeburnis and D. Valiulis, Fast, accurate and reliable
analysis of trace metal air samples involving ultrasonic shaking and
graphite furnace atomic absorption spectroscopy, in: Proceedings
of the 4th European Furnace Symposium and XV Slovak Spectroscopic
Conference, Podbanske, Slovakia, June 12–16, 2000, p. 125
[13] L. Armbruster and H. Breuter, Investigations into defining
inhalable dust, Ann. Occup. Hyg. 26(1), 21–32 (1982),
http://dx.doi.org/10.1093/annhyg/26.1.21
[14] M.R. Bailey, F.A. Fry, and A.C. James, The long-term clearance
kinetics of insoluble particles from the human lung, Ann. Occup.
Hyg. 26(2), 273–290 (1982),
http://dx.doi.org/10.1093/annhyg/26.2.273
[15] A.R. Martin and W.H. Finlay, The effect of humidity on the size
of particles delivered from metered-dose inhalers, Aerosol Sci.
Technol. 39(4), 283–289 (2005),
http://dx.doi.org/10.1080/027868290929314
[16] J.H. Seinfeld and S.N. Pandis, Atmospheric Chemistry and
Physics: From Air Pollution to Climate Change (John Wiley
& Sons, 1998),
http://eu.wiley.com/WileyCDA/WileyTitle/productCd-0471720186.html
[17] K. Okada and J. Heintzenberg, Size distribution, state of
mixture and morphology of Urbam aerosol, J. Aerosol Sci. 34(11),
1539–1553 (2003),
http://dx.doi.org/10.1016/S0021-8502(03)00192-7
[18] Transboundary Particulate Matter in Europe, NILU: EMEP
Report 4/2008,
http://www.nilu.no/projects/ccc/reports/emep4-2008.pdf
[19] Controlling Fine Particulate Matter Under the Clean Air
Act: A Menu of Options (STAPPA, ALAPCO, Washington, 2006),
http://www.mjbradley.com/reports/controlling-fine-particulate-matter-under-clean-air-act-menu-options
[20] G. Mordas, The development of aerosol spectrometry and
application in the investigation of aerosol dynamics, Ph.D. thesis
(Institute of Physics, Vilnius, Lithuania, 2003)
[21] Optical Aerosol Spectrometer LAS 15M (Academy of
Sciences of Lithuania, Institute of Physics, Vilnius, 1990) [in
Russian]